This document provides human-friendly documentation for M2ElectricUserDevice UrbanDataset having semantic definition in the SCP Ontology 2.0, part of the "Smart City Platform Specifications (SCPS) - Semantic Level" developed as part of the Electricity System Research Project. |
|
| File creation date | 2025-12-07 13:19 |
| SCPS URL | https://smartcityplatform.enea.it/#/it/index.html |
This document provides the human-friendly representation of the semantic definition of one or more SCPS ontology´s UrbanDatasets.
Each UrbanDataset is described through a table composed of three main sections:
The normative references concerning the syntactic and semantic compliance of UrbanDatasets with the SCPS are:
| UrbanDataset Identification | ||||
| Scope | Provides information detected by a single-phase or three-phase User Device M"; it supports the main information contained in the Chain2 CF101, CF103 | |||
| Category / Subcategory | EnergyManagement / EnergyDemand | |||
| Identifier | M2ElectricUserDevice-2.0 | |||
| Name | M2 Electric User Device | |||
| URI | https://smartcityplatform.enea.it/specification/semantic/2.0/ontology/scps-ontology-2.0.owl#M2ElectricUserDevice | |||
| UrbanDataset Contextualization | ||||
| Description | Format/Code list | |||
| coordinates | Geographical reference |
Aggregated property | ||
| subProperty: format | Wgs84 format in which the coordinates are expressed (optional attribute) | string FormatCode.gc |
||
| subProperty: height | Altitude (optional property) | double |
||
| subProperty: latitude | Latitude | double |
||
| subProperty: longitude | Longitude | double |
||
| language | The language in which the text fields of the instance are expressed |
string LanguageCode.gc |
||
| timestamp | Timestamp |
dateTime |
||
| timezone | The time zone to be applied to each timestamp in the instance; it is expressed as
an offset, i.e. as + or - the number of hours and minutes respect to UTC time: +/-hh:mm
(ISO 8601) |
string TimezoneCode.gc |
||
| UrbanDataset Properties * properties marked with an asterisk require to indicate, at instance level, the adopted calculation method (e.g. "average", "total", "instantaneous",...) |
||||
| Name | Description | Mandatory | Format/Code list | Unit of Measure |
| ProducedActiveEnergy | Active energy produced in the period (in case of three-phases user device it is the
sum of the phases). It corresponds to the first value of the Chain2 field with OBIS
'1-0:99.1.1.255' |
yes | double |
kilowattHour[default] |
| ProducedActivePower | Active power produced in the period (in case of three-phase user device it is the
sum of the three phases). It corresponds to the Chain2 field with OBIS '1-0:2.27.0.255' |
yes | dateTime |
kilowatt[default] watt |
| TownCode | Municipality ISTAT code |
yes | string TownCode.gc |
|
| UserDeviceID | Identifier of the User Device |
yes | string |
|
| period | Measurement period of the data reported in the row |
yes | Aggregated property | |
| subProperty: end_ts | Timestamp indicating the end of the period | yes | dateTime |
|
| subProperty: start_ts | Timestamp indicating the beginning of the period | yes | dateTime |
|
| timestamp | Timestamp |
yes | dateTime |
|
| Chain2WeaveCode | A code that identifying the Chain2 frame implemented by the UrbanDataset instance |
no | string Chain2WeaveCode.gc |
|
| ElectricityEndUseCode | End use of the electric consumed energy (e.g. lighting, motive power, general, air
conditioning,...) |
no | string ElectricityEndUseCode.gc |
|
| EnergyCommunityID | Energy community identifier |
no | string |
|
| MeterID | A unique identifier for the meter |
no | string |
|
| MeterSchemeID | Indicates the encoding scheme the identifier provided in the MeterID field belongs
to |
no | string |
|
| PODID | Point Of Delivery (POD) identifier |
no | string |
|
| PrimarySubstationID | Primary substation identifier |
no | string |
|
| ProducedActiveEnergyReading | Total produced active energy (corresponding to the value provided by the meter reading
at the end period timestamp). It corresponds to the Chain2 field with OBIS '1-0:2.8.0.255' |
no | double |
kilowattHour[default] |
| ProducedCapacitiveEnergy | Capacitive reactive energy produced in the period (only for three-phase user devices).
It corresponds to the Chain2 field with OBIS '1-0:99.1.5.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| ProducedInductiveEnergy | Inductive energy produced in the period (only for three-phase user devices). It corresponds
to the first value of the Chain2 field with OBIS '1-0:99.1.4.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| ProducedInductiveEnergyReading | Total produced inductive energy (corresponding to the value provided by the meter
reading at the end period timestamp). It corresponds to the Chain2 field with OBIS
'1-0:7.8.0.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| RealEstateUnitID | An identifier for the real estate unit (e.g. apartment, building, independent house...) |
no | string |
|
| SchemeID | Identifies an encoding scheme |