This document provides human-friendly documentation for M1ElectricUserDevice UrbanDataset having semantic definition in the SCP Ontology 2.0, part of the "Smart City Platform Specifications (SCPS) - Semantic Level" developed as part of the Electricity System Research Project. |
|
| File creation date | 2025-12-13 08:53 |
| SCPS URL | https://smartcityplatform.enea.it/#/it/index.html |
This document provides the human-friendly representation of the semantic definition of one or more SCPS ontology´s UrbanDatasets.
Each UrbanDataset is described through a table composed of three main sections:
The normative references concerning the syntactic and semantic compliance of UrbanDatasets with the SCPS are:
| UrbanDataset Identification | ||||
| Scope | Provides information detected by a single-phase or three-phase User Device (M1); it supports the main information contained in the Chain2 CF1, CF2, CF3 and CF4 | |||
| Category / Subcategory | EnergyManagement / EnergyDemand | |||
| Identifier | M1ElectricUserDevice-2.0 | |||
| Name | M1 Electric User Device | |||
| URI | https://smartcityplatform.enea.it/specification/semantic/2.0/ontology/scps-ontology-2.0.owl#M1ElectricUserDevice | |||
| UrbanDataset Contextualization | ||||
| Description | Format/Code list | |||
| coordinates | Geographical reference |
Aggregated property | ||
| subProperty: format | Wgs84 format in which the coordinates are expressed (optional attribute) | string FormatCode.gc |
||
| subProperty: height | Altitude (optional property) | double |
||
| subProperty: latitude | Latitude | double |
||
| subProperty: longitude | Longitude | double |
||
| language | The language in which the text fields of the instance are expressed |
string LanguageCode.gc |
||
| timestamp | Timestamp |
dateTime |
||
| timezone | The time zone to be applied to each timestamp in the instance; it is expressed as
an offset, i.e. as + or - the number of hours and minutes respect to UTC time: +/-hh:mm
(ISO 8601) |
string TimezoneCode.gc |
||
| UrbanDataset Properties * properties marked with an asterisk require to indicate, at instance level, the adopted calculation method (e.g. "average", "total", "instantaneous",...) |
||||
| Name | Description | Mandatory | Format/Code list | Unit of Measure |
| WithdrawnActiveEnergy | Active energy withdrawn (in the case of three phase user device it is the sum of the
phases). It can be calculated as difference between two meter readings. It corresponds
to the Chain2 field with OBIS '1-0:99.1.0.255' |
yes | double |
kilowattHour[default] watthour |
| WithdrawnActiveEnergyReading | Total active energy withdrawn from the grid (corresponding to the value provided by
the meter reading at the end period timestamp). It corresponds to the Chain2 field
with OBIS '1-0:1.8.0.255' |
yes | double |
kilowattHour[default] watthour |
| period | Measurement period of the data reported in the row |
yes | Aggregated property | |
| subProperty: end_ts | Timestamp indicating the end of the period | yes | dateTime |
|
| subProperty: start_ts | Timestamp indicating the beginning of the period | yes | dateTime |
|
| Chain2WeaveCode | A code that identifying the Chain2 frame implemented by the UrbanDataset instance |
no | string Chain2WeaveCode.gc |
|
| ElectricityEndUseCode | End use of the electric consumed energy (e.g. lighting, motive power, general, air
conditioning,...) |
no | string ElectricityEndUseCode.gc |
|
| EnergyCommunityID | Energy community identifier |
no | string |
|
| FeedInActiveEnergy | Active energy fed into the grid in the period (in case of three-phase user device
it is the sum of the phases), to be calculated as the difference between two meter
readings. It corresponds to the Chain2 field with OBIS '1-0:99.1.1.255' |
no | double |
kilowattHour[default] watthour |
| FeedInActiveEnergyReading | Total active energy fed into the grid (corresponding to the value provided by the
meter reading at the end period timestamp). It corresponds to the Chain2 field with
OBIS '1-0:2.8.0.255' |
no | double |
kilowattHour[default] watthour |
| FeedInActivePower * | Power fed into the grid in the period (in case of three phase user device, it is the
sum of the three phases). It corresponds to the Chain2 field with OBIS '1-0:2.27.0.255' |
no | double |
kilowatt[default] watt |
| FeedInCapacitiveEnergy | Capacitive reactive energy fed into the grid in the period (only for three-phase user
devices). It corresponds to the Chain2 field with OBIS '1-0:99.1.5.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| FeedInInductiveEnergy | Inductive energy fed into the grid in the period (only for three-phase user devices).
It corresponds to the first value of the Chain2 field with OBIS '1-0:99.1.4.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| FeedInInductiveEnergyReading | Total inductive energy fed into the grid (corresponding to the value provided by the
meter reading at the end period timestamp). It corresponds to the Chain2 field with
OBIS '1-0:7.8.0.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| MeterID | A unique identifier for the meter |
no | string |
|
| MeterSchemeID | Indicates the encoding scheme the identifier provided in the MeterID field belongs
to |
no | string |
|
| PODID | Point Of Delivery (POD) identifier |
no | string |
|
| PrimarySubstationID | Primary substation identifier |
no | string |
|
| RealEstateUnitID | An identifier for the real estate unit (e.g. apartment, building, independent house...) |
no | string |
|
| SchemeID | Identifies an encoding scheme |
no | string |
|
| TownCode | Municipality ISTAT code |
no | string TownCode.gc |
|
| UserDeviceID | Identifier of the User Device |
no | string |
|
| WithdrawnActivePower * | Power withdrawn from the grid in the period (in case of three-phase user device it
is the sum of the three phases). It corresponds to the Chain2 field with OBIS '1-0:1.27.0.255' |
no | double |
kilowatt[default] watt |
| WithdrawnCapacitiveEnergy | Capacitive reactive energy withdrawn from the grid during the period (only for three
phase user devices), corresponding to the Chain2 field with OBIS '1-0:99.1.3.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| WithdrawnInductiveEnergy | Inductive energy withdrawn from the grid in the period (only for three-phase device).
It corresponds to Chain2 field with OBIS '1-0:99.1.2.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| WithdrawnInductiveEnergyReading | Total inductive energy withdrawn from the grid (corresponding to the value provided
by the meter reading at the end period timestamp). It corresponds to the Chain2 field
with OBIS '1-0:3.8.0.255' |
no | double |
kilovoltamperereactivePerHour[default] voltamperereactivehour |
| coordinates | Geographical reference |
no | Aggregated property | |
| subProperty: format | Wgs84 format in which the coordinates are expressed (optional attribute) | no | string FormatCode.gc |
|